Auto og Marine Odense
 Nyborgvej 703
5220 Odense SØ
+45 40 16 22 44research paper helper
kontakt@automarine.dk
www.automarine.dk

Båtmagneten AB
Fagerdalavägen 11a & 11b
139 52 VÄRMDÖ
tel. 08-571 685 70

Bøges Både Aps
Fabriksvej 2-4
6640 Lunderskov
+45 75 58 58 11
info@boges.dk

www.boges.dk

Jagt og Fiskerimagasinet
Nørre Voldgade 8-10
1358 København K
Tlf: +45 33 33 77 77
Fax: +45 33 14 04 07
mail@jagtogfiskerimagasinet.dk
jagtogfiskerimagasinet.dk

QUESTION 5
An administrator is installing a hypervisor and has provisioned a dedicated LAN connectivity, set the boot order, and is now rebooting the server to start installation. Which method is the administrator using to install the hypervisor?
A. host image mapping
B. KVM console
C. PXE installation
D. virtual boot
Correct Answer: C
Explanation
QUESTION 6
An architect must choose a VXLAN architecture that utilizes hardware-based VXLAN adapters. Which type of architecture must be selected?
A. Layer 3
B. NSX
C. ACI
D. Layer 2
Correct Answer: C
Explanation

70-487 dumps

QUESTION 7
Which three options describe the correct methods to install the Cisco Nexus 1000V VEM (VIB) software module on the VMware ESXi hypervisor? (Choose three.)
A. using the “Add Host to vSphere Distributed Switch” dialog on the vSphere Network tab when Update Manager is installed
B. esxcli software vib install –n/tmp/Cisco_bootbank_cisco-vem –v173-esx_5.2.1.3.1.4.0-3.2.1.vib
C. executing the Deploy-Nexus 1000V-VSEM.ps1 script
D. esxcli software vib install –v/tmp/Cisco_bootbank_cisco-vem –v173-esx_5.2.1.3.1.4.0-3.2.1.vib
E. using the Host Selection dialog box in Cisco Virtual Switch Update Manager
F. creating a baseline group in VMware Update Manager
Correct Answer: ADE
ExplanationExplanation/Reference:
Reference:
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus1000/sw/5_2_1_s_v_3_1_ 4/install/guide/b_Cisco_N1KV_VMware_Install_and_Upgrade_Guide_521SV314/b_Cisco_
N1KV_VMware_Install_and_Upgrade_Guide_521SV314a_chapter_01.html#task_F02BD7 7701B345D9B34A9332AA7C179F
QUESTION 8
An engineer must ensure that all VXLAN and VTEP processes are kept on purpose-built hardware to ensure that all overlay functions are as fast as possible. In which solution is all VXLAN and VTEP decision making moved to the hardware,
versus potentially slower software control?
A. Layer 3
B. ACI
C. NSX
D. Layer 2
Correct Answer: A
Explanation

Kaj Andreasen & Co
Postboks 1200 Brekkutún 7
FO 188 Hoyvík
(+298)31 56 00
www.andreasen.fo

Kenns biler og både 
Ny næstvedvej 1-3a
4683 Rønnede
+45 30 35 42 55

Maritim Center Helsingør Aps
Nordhavnsvej 2B
3000 Helsingør
tlf. 27 79 49 00
www.maritimtcenterhelsingoer.dk

Maritime Engineering A/S
Havnepladsen 4
5960 Marstal
+45 40 25 21 33
mail@maritime-engineering.dk
www.aeroe-marine.dk

Motor og Bådcentret Fr.Havn
Sindallundvej 4
9900 Frederikshavn
+45 98 42 23 93
info@nautisk.dk
www.m-center.dk

Nydam Boats Denmark ApS
Scharffenbergsgade 21
6400 Sønderborg
+45 42 76 44 66

www.nydam-boats.dk

Orsiivik ApS
3900 Nuuk Grønland
Tlf. +299 32 83 93
Mob. +299 52 43 80
www.orsiivik.gl

Predator Sportfishing
Sdr. Boulevard 49
5000 Odense C
Tlf: 72 14 55 14
info@predatorsportfishing.dk
www.predatorsportfishing.dk

Sejs Auto & Marinecenter I/S
Linåvej 9G
8600 Silkeborg
+45 86 84 64 14
info@sejsmarine.com
www.sejsmarine.dk

Sport & Hobby Maribo Jagt og Bådcenter v/ Lars Hansen
Banevænget 1
4930 Maribo
+45 54 78 08 13

Wassersport H. Bonnke GmbH
Tükeslih 11
24887 Silberstedt
Tel.: +49 0 4626 18 48 99 – 0
www.bootszentrum.de